In all cases the specification for the mixture for reinforced concrete should be made after a study of the screen analysis of the coarse and fine aggregates available for usc. No assurance of success can be had by the adoption of arbitrary proportions for the materials to be used. The water content should also be carefully considered and only a sufficient amount of water used' to enable the practical working of the concrete into the forms.
Exterior piers around steel columns should be of reinforced concrete and as large as possible,
Text read from the printed page and cleaned; old type leaves the occasional error.