The following new conditions are added:
27. In the case of performances in bijou theatres not more than 15 pieces of rolled scenery shall be allowed and they shall be rendered and maintained noninflammable.
When required by the Council a fire curtain shall be installed and shall be maintained in good working order and condition. The stage shall not exceed 450 sq. ft, in area, 30 ft, in width and 15 ft. in depth; and the height of the ceiling above the stage floor level shall not exceed 16 ft.
The stage shall be cut off from the auditorium by a proscenium wall of 10" brick of 6" reinforced concrete with only one opening which shall not exceed 20 feet in length and 10 feet in height, except as permitted by the Council, and the stage shall not project more than 18 inches on the outside of the proscenium opening, A: scenery and property store shall be provided and also, if considered necessary by the Council, a workshop. These shall be cut off from the stage if within the stage enclosure by self-closing fire doors.
Dressing rooms shall not exceed a total of 300 sq. ft, in area and shall be cut off from the stage and auditorium in an approved manner.
Flies or musicians' platforms shall not be higher than 7 feet above the stage and approved means of egress therefrom shall be provided.
By order, T. W. GUBB, Acting Secretary.
COUNCIL CHAMBER,
Text read from the printed page and cleaned; old type leaves the occasional error.